PRESSURE
AND TEMPERATURE RATINGS
Maximum
Allowable Non-Shock Pressure, psig.
ANSI/ASME B 16.34-1988
Class 150, 300, & 600
| Service
Temperature |
Class
150 |
Class
300 |
Class
600 |
°F |
°C |
WCB
(a) |
WC1
(b) |
WC6
(c) |
WC9
(c) |
C5 |
WCB
(a) |
WC1
(b) |
WC6
(c) |
WC9
(c) |
C5 |
WCB
(a) |
WC1
(b) |
WC6
(c) |
WC9
(c) |
C5
|
-20
to
100
200
300 |
-29
to
38
93
149 |
285
260
230 |
265
260
230 |
290
260
230 |
290
260
230 |
290
260
230 |
740
675
655 |
695
680
655 |
750
710
675 |
750
715
675 |
750
750
730 |
1480
1350
1315 |
1390
1360
1305 |
1500
1425
1345 |
1500
1430
1355 |
1500
1500
1455 |
400
500
600 |
204
260
316 |
200
170
140 |
200
170
140 |
200
170
140 |
200
170
140 |
200
170
140 |
635
600
550 |
640
620
605 |
660
640
605 |
650
640
605 |
705
665
605 |
1270
1200
1095 |
1280
1245
1210 |
1315
1285
1210 |
1295
1280
1210 |
1410
1330
1210 |
650
700
750 |
343
371
399 |
125
110
95 |
125
110
95 |
125
110
95 |
125
110
95 |
125
110
95 |
535
535
505 |
590
570
530 |
590
570
530 |
590
570
530 |
590
570
530 |
1075
1065
1010 |
1175
1135
1065 |
1175
1135
1065 |
1175
1135
1065 |
1175
1135
1065 |
800
850
900 |
427
454
482 |
80
65
50 |
80
65
50 |
80
65
50 |
80
65
50 |
80
65
50 |
410
270
170 |
510
485
450 |
510
485
450 |
510
485
450 |
500
440
355 |
825
535
345 |
1015
975
900 |
1015
975
900 |
1015
975
900 |
995
880
705 |
950
1000
1050 |
510
538
566 |
35
20
|
35
20
|
35
20
20* |
35
20
20* |
35
20
20* |
105
50
|
280
165
|
380
225
140 |
380
270
200 |
260
190
140 |
205
105
|
560
330
|
755
445
275 |
755
535
400 |
520
385
280 |
1100
1150
1200 |
593
621
649 |
|
|
20*
|
20*
|
20*
20*
20* |
|
|
95
|
115
|
105
70
45 |
|
|
190
|
225
|
205
140
90 |
Hydrostatic
Shell
Test Pressure |
450 |
400 |
450 |
1125 |
1050 |
1125 |
2225 |
2100 |
2250 |
Valve
Closure
Test
Pressure |
Fluid |
314 |
292 |
319 |
814 |
765 |
825 |
1628 |
1529 |
1650 |
Gas |
80 |
80 |
80 |
Notes:
(a)—Permissible, but not recommended for prolonged usage above
about 427°C (800°F).
(b)—Permissible, but not recommended for prolonged usage above
about 454°C (850°F).
(c)—Not to be used over 1100°F.
* For welded end valves only. Flanged end ratings terminate at 538°C